Contact Us
Seals for sub-zero service

Low-Temperature Seals Rated down to -60°C

Elastomer seals and O-rings that stay flexible and keep sealing when the temperature falls, from arctic wellheads and gas blow-down to cold-climate hydraulics.

Most elastomers stiffen and lose their sealing force long before they freeze solid. ISMAT's low-temperature range covers nine grades across four polymer families, each compounded to stay elastic in the cold without giving up the fluid resistance or strength the job needs.

-60°CLowest rated gradeVertex FC 24ULT
+240°CHighest rated gradeVertex F 07LT
9Low-temperature gradesFKM, NBR, HNBR, FFKM
2Grades certified for RGDNORSOK M-710
The cold problem

Why standard seals leak when the temperature drops

An elastomer seals because it is elastic. Squeezed into a groove, it pushes back against the metal faces and keeps pushing as pressure and temperature change. Cold takes that ability away gradually: the polymer chains move closer together and lose their freedom to move, the rubber turns leathery, then stiff and at its glass transition temperature (Tg) it behaves like hard plastic.

01

Loss of resilience

The seal still fills the groove but no longer pushes back hard enough. A small movement in the hardware or a pressure change is enough to open a leak path.

02

Thermal contraction

Elastomers shrink more than ten times as much as steel for every degree of cooling. Squeeze falls just as the material becomes least able to make up for it.

03

Slow response

A stiff seal cannot follow a valve stem, a shaft or a pressure reversal. Leaks often show at start-up or on the first actuation after a cold soak.

04

Cold set and fracture

A seal held compressed in the cold can take a set and leak once it warms up. Below its brittle point, a sudden impact can crack it.

Ambient cold

Oil and gas equipment in Canada, Alaska, Russia and northern Europe runs all year where winter temperatures reach -40°C or lower. High-altitude aircraft systems face similar conditions.

Process cold

When high-pressure gas is vented quickly, during a blow-down for example, the expanding gas cools sharply and can chill valves and seals far below the ambient temperature.

The good news

Cold stiffening is a physical change, not a chemical one. A seal taken below its limit will normally recover as it warms, provided it was not disturbed or shock-loaded while it was brittle.

Grade finder

Find the right low-temperature grade

Each bar shows the operating range from the grade's technical data sheet, on one scale from -60°C to +240°C. Filter by the lowest temperature your equipment will see and by what else the seal has to cope with. Select a grade to open its data sheet page.

Lowest service temperature
Must also handle

Showing all 9 grades

Rapid gas decompression: certified to NORSOK M-710. Sour gas: Vertex FC 15 is certified to NACE TM0187 and API 6A; the Vertex F grades show under 10% volume swell in sour gas on ISMAT's data sheets. All nine grades resist mineral oils and hydrocarbons.

FKM - Fluoroelastomer

Low-temperature FKM seals: fluid resistance that holds down to -60°C

FKM is one of the most widely used high-performance seal materials, but conventional grades typically lose their flexibility somewhere between -15°C and -25°C. ISMAT's low-temperature FKM grades use terpolymer chemistry developed for cold flexibility, so the seal keeps the fuel, oil and chemical resistance that FKM is chosen for at temperatures that would leave a standard grade rigid.

Vertex FC 24ULT is rated from -60°C to +204°C, the lowest limit of any grade on this page, with a compression set of 20% maximum after 22 hours at 200°C. Vertex FC 15 combines a -46°C rating with certification for rapid gas decompression, sour fluid immersion and CO2 decompression, which suits it to cold gas service in oil and gas. Vertex FC 15A is a softer 75 Shore A version with 150% minimum elongation, for seals that need easier fitting or lower sealing force.

-60°CLowest rating
+204°CHighest rating
3Grades
4Certifications (FC 15)

Available as

  • O-rings
  • Back-up seals
  • U-cup seals
  • X-rings
  • Lip seals
  • Wiper seals
  • Packing elements
Trade nameHardnessMin. tempMax. tempKey data and certifications
Vertex FC 24ULT 90±5 -60°C +204°C
  • Lowest-rated grade in the range
  • Compression set 20% max (22 h at 200°C)
  • Tensile strength 14 MPa min
Vertex FC 15 90±5 -46°C +204°C
  • NORSOK M-710 (RGD)
  • API 6A (10% H2S at 200°C)
  • NACE TM0187 (20% H2S) and NACE TM0192 (CO2)
Vertex FC 15A 75±5 -46°C +204°C
  • Softer grade, 150% elongation min
  • Compression set 30% max (70 h at 200°C)
NBR - Nitrile rubber

Low-temperature NBR seals: economical oil resistance to -55°C

Nitrile is the usual choice for oil and fuel service and normally the most economical one. Its low-temperature behaviour depends heavily on the compound, and the trade-off is real: nitrile grades built for the cold tend to swell more in some oils and fuels. The balance between flexibility and fluid resistance has to be set for the job.

Cerulean N 02LT and Cerulean N 04LT are both rated from -55°C to +107°C. N 02LT is an 80 Shore A copolymer NBR with strong resistance to oils and hydrocarbon solvents, used in hoses, pumps, oil seals and cable sealing. N 04LT is a softer 70 Shore A grade with good mechanical strength and abrasion resistance, for valves, pumps, mechanical seals and compressors.

-55°CLowest rating
+107°CHighest rating
2Grades
70-80Shore A

Available as

  • O-rings
  • Back-up seals
  • U-cup seals
  • X-rings
  • Lip seals
  • Wiper seals
  • Packing elements
  • Custom moulded parts
Trade nameHardnessMin. tempMax. tempKey data
Cerulean N 02LT 80±5 -55°C +107°C
  • Copolymer NBR for oils and hydrocarbon solvents
  • Tensile strength 7 MPa min, elongation 120% min
  • Compression set 30% max (22 h at 100°C)
Cerulean N 04LT 70±5 -55°C +107°C
  • Good abrasion resistance and mechanical strength
  • Tensile strength 8 MPa min, elongation 150% min
  • Compression set 30% max (22 h at 100°C)
HNBR - Hydrogenated nitrile

Low-temperature HNBR seals: strength and RGD resistance in the cold

HNBR is nitrile whose polymer backbone has been saturated by hydrogenation. It keeps the oil resistance of NBR and adds higher mechanical strength, better heat resistance and much better resistance to ozone and weathering, which matters for equipment that stands outdoors through the winter.

Both Vertex H grades are rated from -46°C, with short-term exposure to -52°C. Vertex H 17 is certified to NORSOK M-710 for rapid gas decompression and to NACE TM0192 for CO2 decompression. Its typical results include a tensile strength of 19 MPa, a compression set of 5.4% after 22 hours at 150°C and a TR10 of -37°C. Vertex H 18LT is an 85 Shore A grade rated to +150°C, for valves, pumps, mechanical seals and compressors.

-46°CLowest rating (-52°C short-term)
+160°CHighest rating
2Grades
-37°CTR10, Vertex H 17

Available as

  • O-rings
  • Back-up seals
  • U-cup seals
  • X-rings
  • Lip seals
  • Wiper seals
  • Packing elements
  • Custom moulded parts
Trade nameHardnessMin. tempMax. tempKey data and certifications
Vertex H 17 87 (typical) -46°C
-52°C short-term
+160°C
  • NORSOK M-710 (RGD) and NACE TM0192 (CO2)
  • TR10 -37°C (ASTM D1329)
  • Compression set 5.36% (22 h at 150°C), typical
Vertex H 18LT 85±5 -46°C
-52°C short-term
+150°C
  • Better oil and ozone resistance than NBR
  • Tensile strength 14 MPa min
  • Compression set 25% max (22 h at 150°C)
FFKM - Perfluoroelastomer

Low-temperature FFKM seals: cold service with aggressive chemicals

FFKM is fully fluorinated, which gives it the widest chemical resistance of any elastomer. Most FFKM grades are designed for heat rather than cold. ISMAT's standard Vertex F grades, such as Vertex F 02, are rated to -10°C.

Vertex F 02LT and Vertex F 07LT extend that limit to -40°C. They resist hot organic and inorganic acids, caustics, amines, ketones, aldehydes, esters, ethers, alcohols, fuels, solvents, sour gases, hydrocarbons, steam, hot water, ethylene and propylene oxide and mixed process streams. F 02LT (75 Shore A) is rated to +230°C; F 07LT (90 Shore A) is rated to +240°C, and its higher hardness helps where extrusion resistance matters.

-40°CLowest rating
+240°CHighest rating
2Grades
<10%Swell, most media

Volume swell, Vertex F 02LT and F 07LT

Inorganic acids<10%
Organic acids<10%
Alkalis<10%
Amines (room temp.)<10%
Water and steam<10%
Ketones<10%
Esters<10%
Ethers<10%
Aldehydes<10%
Alcohols<10%
Hydrocarbons<10%
Sour gas<10%
Lubricants<10%
Hot amines (>70°C)10-30%
Fluorinated fluids30-50%

Source: ISMAT technical data sheets, Vertex F 02LT and F 07LT.

Available as

  • O-rings
  • Gaskets
  • Diaphragms
  • Pump housing seals
Trade nameHardnessMin. tempMax. tempKey data
Vertex F 02LT 75±5 -40°C +230°C
  • Under 10% swell in acids, alkalis, amines, ketones, steam and sour gas
  • Elongation 120% min
  • Compression set 30% max (24 h at 200°C)
Vertex F 07LT 90±5 -40°C +240°C
  • Same chemical resistance as F 02LT at 90 Shore A
  • Tensile strength 11.3 MPa min
  • Compression set 30% max (24 h at 200°C)

Limits: do not use any Vertex F grade with molten alkali metals. Hot amines above +70°C cause 10-30% swell and fluorinated fluids 30-50%, so check these media with ISMAT before specifying.

Technical data

Compare all nine low-temperature grades

Specification values from ISMAT's technical data sheets. Values marked * are typical test results; all others are specification limits.

Swipe the table sideways to see every column →

GradeHardness, Shore ADensity, g/ccTensile, MPaElongation, %Compression setOperating rangeCertifications
Terpolymer FKM - Vertex FC
Vertex FC 24ULT90±51.85±0.0514 min80 min20% max (22 h/200°C)
35% max (70 h/200°C)
-60°C to +204°C-
Vertex FC 1590±51.85±0.0510 min80 min25% max (22 h/200°C)
35% max (70 h/200°C)
-46°C to +204°CNORSOK M-710, API 6A, NACE TM0187, NACE TM0192
Vertex FC 15A75±51.85±0.0510 min150 min30% max (70 h/200°C)-46°C to +204°C-
NBR - Cerulean N (N 02LT is a copolymer NBR)
Cerulean N 02LT80±5-7 min120 min30% max (22 h/100°C)
50% max (70 h/100°C)
-55°C to +107°C-
Cerulean N 04LT70±5-8 min150 min30% max (22 h/100°C)
50% max (70 h/100°C)
-55°C to +107°C-
Hydrogenated nitrile (HNBR) - Vertex H
Vertex H 1787*1.304*19.02*143.44*5.36%* (22 h/150°C)
11.86%* (70 h/150°C)
-46°C to +160°C
-52°C short-term
NORSOK M-710, NACE TM0192
Vertex H 18LT85±51.30±0.0514 min100 min25% max (22 h/150°C)-46°C to +150°C
-52°C short-term
-
Perfluoroelastomer (FFKM) - Vertex F
Vertex F 02LT75±51.95±0.0510 min120 min30% max (24 h/200°C)-40°C to +230°C-
Vertex F 07LT90±52.0±0.0511.3 min80 min30% max (24 h/200°C)-40°C to +240°C-

Test methods: hardness ASTM D2240; density ASTM D792; tensile strength and elongation ASTM D412; compression set ASTM D395 Method B; TR10 ASTM D1329. Full data sheets can be downloaded from each grade page.

Reading a low-temperature rating

How low-temperature performance is measured

A low-temperature figure is only useful if you know how it was measured. Each test describes something different and two tests on the same compound can give answers several degrees apart.

ASTM D1329 / ISO 2921

TR10, temperature retraction

A specimen is stretched, frozen and then warmed slowly. TR10 is the temperature at which it has recovered 10% of the stretch, close to the point where it starts to behave like rubber again. It is the most practical single figure for comparing seal compounds.

ASTM D3418 (DSC)

Tg, glass transition

The temperature below which the polymer is glass-like. A seal does not work there. TR10 usually sits a few degrees above Tg.

ASTM D2137

Brittleness point

The lowest temperature at which a specimen survives an impact without cracking. It shows the material will not shatter, not that it will still seal.

ASTM D1053 (Gehman)

Torsional stiffness

Measures how stiff the rubber becomes as it cools. The temperature at which the modulus reaches 70 MPa (T70) is often taken as the limit of useful flexibility and usually falls close to TR10.

ASTM D1229

Low-temperature compression set

Measures how well a compressed specimen recovers after cold exposure. Because it reproduces the way a seal is loaded, it is a good guide to real sealing behaviour.

Functional testing

Product-configured tests

The most reliable check is a seal tested in a housing that reproduces the real groove fill, squeeze, surface finish, pressure and media. Laboratory tests compare compounds; functional tests confirm the design.

Turning TR10 into a working limit

A widely used guideline for O-rings and other compression seals: a dynamic seal should not run below its TR10, while a static seal in a well-designed groove typically seals to about 8°C below it.

At or above TR10Dynamic seals
About TR10 - 8°CStatic seals
8°C static margin
-52°CShort-term
-46°CRated limit
-37°CTR10

Example: Vertex H 17 has a measured TR10 of -37°C. Applying the static guideline gives about -45°C, close to its -46°C rated limit. For a dynamic seal, plan on -37°C.

The operating temperatures on this page are taken from each grade's technical data sheet. For dynamic duty near the lower limit or where a rating must be tied to a specific test, ask ISMAT for the test data on the grade you are considering.

Design guidance

Designing a seal for cold service

The compound is the starting point, not the whole answer. These factors change how low a given material will actually seal in your equipment.

  1. Allow for pressure

    Pressure raises the glass transition temperature, by roughly 1°C for every 52 bar (750 psi). A compound that seals at -40°C at low pressure may not do so at several hundred bar.

  2. Pressurise before cooling

    Seals pressurised before they cool tend to seal at lower temperatures than seals pressurised when they are already cold and stiff.

  3. Prefer one pressure direction

    A seal loaded from one side moves less in its groove than one that sees pressure reversals, so it holds a seal better in the cold.

  4. Set squeeze for the coldest point

    More squeeze helps static seals at low temperature, but it must be balanced against fitting damage and against thermal expansion if the system also runs hot. Check groove fill at the lowest temperature, not only at assembly.

  5. Know what the media does

    A small amount of swell from hydrocarbons softens the seal and raises interference, which helps. Fluids that extract plasticiser do the opposite and leave a harder, smaller seal. Share the full fluid list with us.

  6. Design for the dry condition

    Lubrication improves low-temperature sealing, but it can be wiped away in service. Base the design on the unlubricated seal.

  7. Check housing and finish

    Groove geometry and surface finish both affect how a stiffening seal behaves. Where cold and high pressure combine, back-up rings protect the seal from extrusion.

  8. Confirm with a functional test

    For critical service, test the seal in a fixture that reproduces the real housing, pressure and media before you commit to it.

Colder than -60°C?

Move from elastomers to engineered plastics

Below -60°C, and in cryogenic service such as LNG and liquid nitrogen, elastomers are no longer the right material. For these conditions ISMAT uses PTFE and PCTFE grades from the Novum range, including spring-energised seals that supply the sealing force the material cannot.

Cryogenic seals
Product range

Low-temperature seals in every format

High performance O-rings
O-rings Back-up rings X-rings Packing elements U-cup seals Lip seals Wiper seals Gaskets and diaphragms Custom moulded parts Something else? Ask us
Questions

Low-temperature seals: common questions

If your question is not answered here, ISMAT's engineers will help you choose a grade.

Ask an engineer

What is the lowest temperature ISMAT's elastomer seals can handle?

Vertex FC 24ULT, a terpolymer FKM, is rated from -60°C to +204°C. The Cerulean N 02LT and N 04LT nitrile grades reach -55°C, the Vertex H 17 and H 18LT HNBR grades -46°C (-52°C short-term) and the Vertex F 02LT and F 07LT perfluoroelastomers -40°C. Below -60°C, ISMAT uses PTFE and PCTFE cryogenic seals instead.

What is TR10 and why does it matter?

TR10 (ASTM D1329, ISO 2921) is the temperature at which a stretched, frozen rubber specimen has retracted by 10% as it warms. It marks roughly where the compound starts to behave like rubber again, so it is the most practical single figure for comparing seal compounds. As a guide, a dynamic seal should not run below its TR10, while a static seal in a well-designed groove typically seals to about 8°C below it.

Will a seal recover after going below its low-temperature limit?

Usually, yes. Cold stiffening is a physical change, so a seal normally returns to its original properties when it warms up, provided it was not disturbed or shock-loaded while brittle. The real risks are leakage while the seal is cold and compression set if it was held squeezed in the cold.

Which low-temperature grades are certified for rapid gas decompression?

Vertex FC 15 (FKM, -46°C) and Vertex H 17 (HNBR, -46°C) are certified to NORSOK M-710 for rapid gas decompression and to NACE TM0192 for CO2 decompression. Vertex FC 15 is also certified to NACE TM0187 (sour fluid immersion, 20% H2S) and to API 6A (10% H2S at 200°C).

NBR, HNBR or FKM: which should I choose for cold oil service?

NBR is the most economical choice for mineral oils, greases and fuels within -55°C to +107°C. HNBR adds mechanical strength, heat resistance to +150°C or +160°C and much better ozone and weather resistance. FKM is the choice when the fluid or temperature is beyond HNBR, for example aromatic fuels, many chemicals or continuous service up to +204°C. FFKM covers aggressive chemicals that FKM cannot handle.

Does system pressure affect low-temperature sealing?

Yes. Pressure raises the glass transition temperature of an elastomer by roughly 1°C for every 52 bar (750 psi), so high-pressure gas service needs more margin below the rated limit. Applying pressure before the seal cools also tends to improve low-temperature sealing.

Where can I get data sheets and chemical compatibility data?

Each grade page has a downloadable technical data sheet, and the ISMAT Chemical Compatibility Guide covers media resistance across all materials. For test data beyond the data sheet, such as TR10 or certification reports, contact ISMAT.

Get in touch

Tell us how cold it gets

Send the operating conditions below and ISMAT's engineers will recommend a grade and share the test data behind the recommendation.

  • Lowest and highest temperature
  • Media, including cleaning fluids
  • Pressure and its direction
  • Static or dynamic duty
  • Groove or seal dimensions
  • Certifications you need

The information on this page is accurate and reliable to the best of ISMAT's knowledge, but it does not guarantee the performance of a finished part. Customers should evaluate parts before use, especially in applications where failure could cause injury or damage.